Pressure Tank Volume Formula:
From: | To: |
Definition: This calculator estimates the required volume of a pressure tank based on the desired drawdown capacity and system pressure factor.
Purpose: It helps plumbers, engineers, and homeowners properly size pressure tanks for water systems.
The calculator uses the formula:
Where:
Explanation: The drawdown is multiplied by the pressure factor to determine the minimum tank size needed to provide the desired water volume between pump cycles.
Details: Correct tank sizing prevents short cycling of pumps, maintains consistent water pressure, and extends equipment life.
Tips: Enter the required drawdown volume in gallons and the pressure factor (default 0.33 for typical 40/60 psi systems). All values must be > 0.
Q1: What is drawdown volume?
A: The amount of water available between pump cycles (from cut-in to cut-out pressure).
Q2: How is pressure factor determined?
A: It's calculated as (Pcut-in × Pcut-out) / (Pcut-out - Pcut-in).
Q3: What's a typical pressure factor?
A: For common 40/60 psi systems, it's 0.33 (20/40 psi = 0.25, 30/50 psi = 0.375).
Q4: How do I find my drawdown requirement?
A: Estimate based on peak demand or use 1 gallon per minute of pump capacity.
Q5: Does this account for bladder tanks?
A: Yes, the calculation works for both bladder-type and conventional pressure tanks.